( Brand: Wayne Kerr / Farnell ), ( Manufacturer Part Number: AMM20002Q ), ( Model: AUTOMATIC MODULATION METER AMM20002Q 1.5KHZ-2.4GHZ ), ( Part Type: Meter )
The AMM20002Q Kerr Metter is an automatic modulation meter designed for use in the frequency range of 150 kHz to 2.4 GHz. This high-performance device is ideal for applications that require precise and accurate measurement of modulation parameters in various radio frequency (RF) and microwave systems.
The AMM20002Q Kerr Metter features an automatic modulation measurement capability, which eliminates the need for manual adjustments and calculations, making it a time-saving solution for engineers and technicians. The meter supports a wide range of modulation types, including amplitude modulation (AM), frequency modulation (FM), phase modulation (PM), and pulse modulation (PM).
The instrument offers a high frequency range of 150 kHz to 2.4 GHz, making it suitable for use in a variety of RF and microwave systems, including wireless communication systems, radar systems, and test and measurement equipment. The device has a built-in high-resolution digital display that provides real-time measurements of modulation depth, deviation, and other relevant parameters.
The AMM20002Q Kerr Metter is equipped with a high-sensitivity and wideband tuner, which ensures accurate and reliable measurements even in noisy environments. The instrument also features an automatic calibration function, which helps to maintain its accuracy over time and ensures that the measurements are traceable to national and international standards.
The AMM20002Q Kerr Metter is easy to use, with a user-friendly interface and intuitive controls. The device can be powered using an external power source or a rechargeable battery, providing flexibility and portability. The meter is also compact and lightweight, making it easy to transport and use in the field.
Overall, the AMM20002Q Kerr Metter is a powerful and versatile modulation meter that is ideal for applications in RF and microwave systems. Its automatic measurement capability, wide frequency range, high sensitivity, and easy-to-use interface make it a reliable and accurate tool for engineers and technicians.
Pros of buying a 150kHz-2.4GHz AMM20002Q Kerr Meter from Farnell:1. Automatic operation: The meter is designed to operate automatically, which can save time and reduce the risk of human error.
2. Wide frequency range: The meter covers a wide frequency range of 150kHz to 2.4GHz, making it suitable for a variety of applications.
3. High accuracy: The meter is designed to provide high accuracy measurements, which is important for many applications.
4. Easy to use: The meter has a user-friendly interface and is easy to operate, even for those who are not experienced with Kerr meters.
Cons of buying a 150kHz-2.4GHz AMM20002Q Kerr Meter from Farnell:1. Price: The meter is relatively expensive compared to other Kerr meters on the market.
2. Limited availability: The meter may not be widely available in all regions, which could make it difficult to obtain.
3. Requires specific knowledge: The meter requires specific knowledge of Kerr measurements and modulation techniques, which may not be familiar to all users.
Conclusion:The 150kHz-2.4GHz AMM20002Q Kerr Meter from Farnell is a high-quality, automatic Kerr meter with a wide frequency range and high accuracy. However, its high price and limited availability may make it a less attractive option for some users. If you have the specific knowledge required to use the meter and can afford its price, it could be a valuable tool for your applications. Alternatively, you may want to consider other Kerr meters with a more affordable price and wider availability.
Recommendation:If you are in need of a Kerr meter with a wide frequency range and high accuracy, the 150kHz-2.4GHz AMM20002Q Kerr Meter from Farnell could be a suitable option for you. However, consider your budget and availability options before making a decision. If you are unsure, you may want to consult with an expert or do further research to determine if this meter is the best fit for your needs.
These values can either be linear or db. Photos show everything that is included. Resolutions of 10 hz an. Carrier levels can be measured in DBMS or MW over a range of 6 DBMS to 20 DBMS.
The keyboard is a sealed tactile membrane front panel with an RIF shield laminated in it. Comes from a working environment. 1742 Gama fsr45 row The modulation meter has a low noise figure.
This maximizes the resolution for narrow band and unwanted modulation measurements. 4 ghz frequency range. This allows for measurements on high data rate systems. 4ghz Farnell the modulation meter AMM20002Q is a portable full featured modulation meter.
The internal ram can store user defined setups. The large FM deviation is useful when measuring wide band telemetry systems. The glib hip connector is bent refer to pictures.
When making residual noise measurements, digital averaging can be selected. 14 day right of return if not satisfied. A taxi reference is fitted as a standard with an aging rate of e 6 per year. Modulation measurement capability Islam, 500 khz pk FM, and 50 rad pm.
A rear panel AF input jack enables base band signals for level and frequency to be analyzed. All measurements are shown on a highly visible 32 character alphanumeric led. Great unit.
1 hz can be expected over the RF and AF ranges respectfully. This range covers virtually all radio services in MFA, hf, vhf, Ind uhf bands. An accuracy of better than 1 is achieved using the built in digital self calibration source. A 20 segment analog led bar graph is useful when viewing peaks and trends.
Wayne Kerr AMM20002Q automatic modulation meter 150khz This ram also allows rapid switching between predetermined tests. I never needed this when I used this unit. The meter is equipped with three high pass and four low pass filters, an FM de emphasis mode, and peak or true RMS level modes.
These features provide post carrier detection signal conditioning. Easy to use. Individual memories are available for recall, store, and protect. The display can be set to give absolute or relative values.
Maximum sensitivity for modulation and frequency measurement is 30 DBMS. The keyboard is used for manual tuning. This is ideal for use in automatic test systems.
A microprocessor automatically locks onto the strongest carrier frequency. The modulation band width is 10 hz to 300 khz. The meter can also be used as a frequency counter. Excess power protection is provided at the instrument RF input for signals up to 25 w and down to 250 MW.
Measurements with a peak hold are available for burst capture. Manual operation of the meter is performed using the keyboard. Carrier levels up to 30 DBMS can be measured using an external 10 db attenuate pad maximum continuous power 1 w.
It can put settings and output measurements. Remote control operations are available through a glib interface. It measures signals in the 150 khz to A built in digital self calibration source is used for am, FM, and pm measurements.