
( Brand: Ortec ), ( Manufacturer Part Number: GEM-35175-S ), ( Part Type: Angle Dipstick Detector ), ( Country/region Of Manufacture: United States )
The ORETec Gem HPGE Detector Angle Dipstick Cryostat (Model: gem-35175-s) is a high-performance, versatile cryostat designed for use with HPGE (High Purity Germanium) detectors. This device is specifically engineered to provide optimal performance and ease of use in various laboratory applications, including gamma spectroscopy and nuclear physics research.
The gem-35175-s features an innovative angle dipstick design, allowing for optimal detector alignment with the radiation source. This results in improved efficiency and reduced background noise, leading to more accurate and reliable data. The cryostat is equipped with a high-quality, vacuum-sealed dewar flask, ensuring stable temperatures and minimal heat leakage. The flask is also fitted with a removable, adjustable angle dipstick, enabling users to easily adjust the detector angle for optimal positioning.
The ORETec Gem HPGE Detector Angle Dipstick Cryostat is designed with a robust, yet lightweight construction, making it easy to transport and handle. It is made from high-quality materials, including stainless steel and vacuum-sealed glass, ensuring durability and longevity. The device is also equipped with safety features, such as a pressure relief valve and a vacuum-sealed lid, to prevent damage and ensure user safety.
The gem-35175-s is compatible with a wide range of HPGE detectors, making it a versatile tool for a variety of applications. Its high-efficiency design and ease of use make it an excellent choice for researchers and scientists looking for accurate and reliable data in the field of gamma spectroscopy and nuclear physics. Overall, the ORETec Gem HPGE Detector Angle Dipstick Cryostat is a high-quality, reliable, and user-friendly device that is sure to meet the needs of even the most demanding laboratory applications.
Pros of buying a OTREC Gem HPGE Detector Angle Dipstick Cryostat (Gem-35175):1. High Efficiency: The detector has a high efficiency, which means it can detect more particles than other detectors with the same size, resulting in better data quality and shorter counting times.
2. Angle Dipstick Design: The angle dipstick design allows for easy positioning of the detector, ensuring optimal geometry for maximum sensitivity.
3. Cryostat Integration: The integrated cryostat keeps the detector at the optimal temperature, improving performance and reducing the need for external cooling systems.
4. Durable Construction: The detector is made of high-quality materials, ensuring durability and long-lasting performance.
5. Compatibility: The detector is compatible with many different types of particle detectors and counting systems, making it a versatile addition to any lab.
Cons of buying a OTREC Gem HPGE Detector Angle Dipstick Cryostat (Gem-35175):1. High Cost: The detector is expensive, which may be a barrier for some users with limited budgets.
2. Requires Expertise: The detector requires expertise to operate and maintain, which may be a challenge for users without a strong background in nuclear physics.
3. Limited Availability: The detector may be difficult to find in some regions, which may impact delivery times and availability.
4. Complex Setup: The detector has a complex setup process, which may be time-consuming and require specialized tools.
5. Potential for Breakage: The detector is made of fragile materials and may be susceptible to breakage if not handled with care.
Conclusion:The OTREC Gem HPGE Detector Angle Dipstick Cryostat (Gem-35175) is a high-quality detector that offers superior performance and versatility. Its angle dipstick design, high efficiency, and integrated cryostat make it an excellent choice for users in the nuclear physics field. However, its high cost, complex setup, and potential for breakage may make it a less attractive option for users with limited budgets or expertise.
Recommendation:If you have the expertise and budget to operate and maintain the OTREC Gem HPGE Detector Angle Dipstick Cryostat (Gem-35175), it is a worthwhile investment that will improve your lab's data quality and efficiency. However, if you are a beginner or have limited resources, consider alternative detectors that offer similar performance at a lower cost.
This equipment cannot be exported to some countries. The pre amplifier has been adjusted for optimal performance with new feat. Buyers should understand correct handling and operating procedures for these sensitive fragile detectors. The detector is mounted in a right-angle dipstick cryostat that fits 30-liter liquid nitrogen Dewar.
The back shell to power plug is loose, which has no bearing on functionality but buyer may wish replace it. It has a rugged aluminum housing.
It comes with a standard Ortec HIV filter and shiv pigtail accepting 3.
I recommend a shaping time of 4-6 microseconds Gaussian with this particular detector. Pickup in Albuquerque is free. Since it has just been pumped, the cryostat vacuum should remain good for many years.
A new jet, specially selected for high trans conductance and good linearity, has been installed within the cryostat to replace original damaged one, undergone two high-temperature baking cycles attached dry turbo molecular vacuum pumping station. Foreign buyers must contact me prior to buying.