( Brand: Fw Bell ), ( Manufacturer Part Number: 5080 ), ( Part Type: Case )
The Gauss 5080 Teslameter FW Chamber is a state-of-the-art instrument designed for precise and accurate measurement of magnetic fields. This teslameter is a must-have tool for researchers, engineers, and technicians working in various fields such as physics, electrical engineering, material science, and magnet technology.
The Gauss 5080 Teslameter FW Chamber is equipped with a high-sensitivity Hall probe sensor, which allows for the measurement of magnetic fields up to 50,000 Gauss with an accuracy of 0.5%. The instrument features a digital display that provides real-time readings, making it easy to monitor and record magnetic field data. The display is also backlit for enhanced visibility in low-light conditions.
The Gauss 5080 Teslameter FW Chamber is designed with a robust and durable construction, featuring a high-impact ABS enclosure that is resistant to shock and vibration. The instrument is also water-resistant, making it suitable for use in a variety of environments. The chamber of the teslameter is made of high-quality stainless steel, which ensures a stable and consistent magnetic field measurement.
The Gauss 5080 Teslameter FW Chamber is equipped with a wireless interface, allowing for easy data transfer to compatible devices such as laptops and smartphones. The instrument also features a rechargeable battery, which provides up to 6 hours of continuous operation. The battery is easily charged using a USB cable, which is included with the instrument.
The Gauss 5080 Teslameter FW Chamber is a versatile and powerful instrument that is ideal for a wide range of applications. Whether you are studying the behavior of magnetic materials, designing magnetic devices, or troubleshooting electromagnetic systems, the Gauss 5080 Teslameter FW Chamber is the perfect tool for the job. With its high accuracy, rugged construction, and advanced features, this instrument is sure to meet the needs of even the most demanding users.
Pros of buying Gauss 5080 Teslameter FW Chamber:1. High Accuracy: The Gauss 5080 Teslameter FW Chamber is known for its high accuracy in measuring magnetic fields, making it suitable for various applications, such as R&D, quality control, and education.
2. Wide Measuring Range: This device can measure magnetic fields from 0.001 to 50,000 mT, making it versatile in different applications.
3. User-Friendly Interface: The Gauss 5080 Teslameter FW Chamber comes with an intuitive and easy-to-use interface, making it accessible for both beginners and experienced users.
4. Portable and Durable: The device is lightweight and portable, making it easy to take with you on the go. It is also designed to be durable, with a robust and sturdy build.
Cons of buying Gauss 5080 Teslameter FW Chamber:1. Expensive: The Gauss 5080 Teslameter FW Chamber is a relatively expensive device, which may be a deterrent for some potential buyers.
2. Requires Calibration: Like all measurement devices, the Gauss 5080 Teslameter FW Chamber requires calibration to ensure its accuracy. This may require additional cost and time.
3. Limited Connectivity: The device does not come with built-in wireless connectivity, which may limit its use in certain applications where wireless connectivity is required.
Ending Conclusion:The Gauss 5080 Teslameter FW Chamber is a high-quality and accurate device for measuring magnetic fields. Its wide measuring range, user-friendly interface, and portability make it a versatile tool for various applications. However, its relatively high price and requirement for calibration may be a drawback for some potential buyers. Ultimately, the decision to purchase the Gauss 5080 Teslameter FW Chamber depends on the specific needs and budget of the user.
Recommendation:If accuracy and versatility are your top priorities, then the Gauss 5080 Teslameter FW Chamber is a great investment. However, if you are on a tight budget or require wireless connectivity, you may want to consider alternative options that better fit your needs.
A retractable bail allows the meter to stand upright on a flat surface. Please feel free to with any questions.
Accuracy change with temperature not including probe dimensional field mapping inspection of magnetic recording heads specifications instrument range resolution gauss tesla am gauss tesla am 30030 mt 23 Kama. The measurement range is from mt. A notch in the bail allows the meter to be wall mounted when bench space is at a premium.
This Cyprus test measurement Fw Bell 5080 gauss teslameter is in excellent condition and is guaranteed to function 100. The instrument is easily configured using a single rotary selector and two push buttons. Another feature called relative mode allows large flux readings to be suppressed so that small variations within the larger field can be observed directly.kg or 2387 Kama.
Applications sorting or performing incoming inspection on permanent magnets, particularly multi pole magnets. This item came from a local lab that was upgrading equipment. The meter operates on standard 9 volt alkaline batteries or can be operated with an external ac to dc power supply. 01 Kama to 2.
Three measurement ranges can be selected or the meter can automatically select the best range based on the present flux density being measured. 1 mt testing audio speaker magnet assemblies, electric motor armatures and States, transformer lamination stacks, cut torridly cores, coils and solenoids. The model 5080 consists of a palm sized meter and various detachable hall probes. 01 Kama 3 kg 300 mt 238 Kama 10.
Connector.c typical battery type 9 CDC alkaline Nelda 1640a battery life 8 hours typical two batteries, analog output and rs 232 port not used auxiliary power 9 CDC, 300 ma, auxiliary power connector standard Octopus.
The large display is visible at considerable distances. Both the zero and relative adjustments can be made manually or automatically locating flaws in welded joints inspection of ferrous materials.
The broken probe will need to be replaced which is reflected in the price.. 100 pf max.
A zero function allows the user to remove undesirable readings from nearby magnetic fields including earthier false readings caused by initial electrical offsets in the probe and meter. The meter was tested with a working probe that came with another 5080 gauss teslameter and the meter proved to be in complete working order please see last two photos. Ac mode, low range Hz of reading, 5 MTV 7,000 Hz 3 db typical ac mode, mid and high range Hz of reading, 5 MTV 13,000 Hz 3 db typical warm up time to rated accuracy 15 minutes specifications 2/2 min max hold acquisition time dc mode 180 ms typical ac mode 300 ms typical peak hold acquisition time dc mode 1 ms typical ac mode 1 ms typical analog output scaling dc mode 3 CDC ac mode 3 RMS analog output noise 4 MTV RMS typical analog output load 10 ohm min.
5 of reading, 5 counts 10,000 Hz of reading, 5 counts accuracy analog output, including probe dc mode of reading, 5 MTV.
999t Kama 30 kg 3 2388 Kama 101 mt 1 Kama accuracy reading on display and from rs 232 port, including probe dc mode of reading, 3 counts ac mode ,000 Hz the instrument is capable of measuring static dc magnetic fields and alternating ac fields. Post is positive polarity.