9524A Emi Photomultiplier Tubes Rank Hilger Scintillation Crystal

9524a 7 Emi Photomultiplier Tubes

( Model: 9524A ), ( Country/region Of Manufacture: United Kingdom ), ( Type: Photomultiplier Tubes )

Review Emi Photomultiplier Tubes Rank Hilger Scintillation Crystal Ti

The 9524A EMI Photomultiplier Tube (PMT) from Hilger is a high-performance device designed for applications in the field of scintillation detection. This photomultiplier tube is specifically engineered to operate in the presence of electromagnetic interference (EMI), making it an ideal choice for use in noisy environments.

The 9524A PMT features a 2-inch diameter photocathode, which provides a large active area for maximizing the efficiency of photon detection. The photocathode is made of a high-quantum-efficiency bialkali material, ensuring excellent sensitivity to a wide range of photon energies. The tube's photocathode is also protected by a 0.5-mm thick beryllium window, which allows for efficient light transmission while providing mechanical strength and resistance to radiation damage.

The 9524A PMT is a dual-anode design, with two separate anodes for positive and negative charges. This configuration allows for the measurement of the charge spectrum of incoming photons, which can provide valuable information about the energy of the photons. The anodes are made of a low-noise material, ensuring accurate and reliable detection of the small signals produced by the photomultiplier tube.

The 9524A PMT is also equipped with a built-in high voltage (HV) supply, which simplifies the setup and operation of the device. The HV supply can be adjusted from 0 to 2000 volts, allowing for fine-tuning of the photomultiplier tube's gain and sensitivity. The tube is also equipped with a built-in current limiting circuit, which protects the photomultiplier tube from damage in case of a short circuit or other electrical fault.

The 9524A PMT is designed for use with scintillation crystals, which convert incoming photons into visible light. Hilger offers a range of scintillation crystals that are compatible with this photomultiplier tube, including NaI(Tl) and LaBr3. These crystals are available in various sizes and shapes, allowing for flexibility in the design of scintillation detection systems.

In summary, the 9524A EMI Photomultiplier Tube from Hilger is a high-performance device designed for use in scintillation detection systems. It features a large active area, high-quantum-efficiency photocathode, and dual-anode design, which allows for accurate and reliable detection of photons. The tube also includes a built-in HV supply and current limiting circuit, simplifying setup and operation. Compatible scintillation crystals are available from Hilger, ensuring a complete solution for scintillation detection applications.

Pros of buying 9524a EMI Photomultiplier Tubes (PMTs) with Hilger scintillation crystals:

1. High sensitivity: The 9524a PMTs are known for their high photon detection efficiency, making them suitable for applications that require sensitivity to low-level light signals.

2. Wide dynamic range: These PMTs can handle a wide range of input photon counts, making them versatile for various applications.

3. Excellent signal-to-noise ratio: The combination of the 9524a PMT and Hilger scintillation crystals results in a low noise signal, which is essential for high-precision measurements.

4. Reliability: These PMTs are built with robust materials and construction, ensuring long-term reliability and stability in various environments.

5. Availability of various options: Hilger offers a wide range of scintillation crystals, allowing customers to choose the one that best matches their specific application requirements.

Cons of buying 9524a EMI Photomultiplier Tubes with Hilger scintillation crystals:

1. Cost: The combination of high-quality PMTs and scintillation crystals can be expensive, which might be a limiting factor for some budget-conscious customers.

2. Complex setup: The selection of the right scintillation crystal and proper alignment can be challenging and time-consuming, requiring specialized knowledge and expertise.

3. Sensitivity to EMI: The 9524a PMTs are sensitive to Electromagnetic Interference, which can lead to noise and signal degradation if not properly shielded.

Conclusion:

The 9524a EMI Photomultiplier Tubes with Hilger scintillation crystals are a powerful combination for various applications that require high sensitivity, wide dynamic range, and low noise signals. Despite the higher cost and complex setup, the benefits of these components, such as their excellent performance and reliability, make them a worthwhile investment for many research and industrial applications.

Recommendation:

If you are looking for high-performance PMTs and scintillation crystals for your research or industrial application, consider the 9524a EMI Photomultiplier Tubes and Hilger's wide range of scintillation crystals. For best results, make sure to consult with an experienced expert or seek proper training on how to select, align, and handle this equipment.

Details:

Up for purchase is seven emi 9524A photomultiplier tubes, one rank hilger scintillation crystal na ti, that has the engraved on it, various ND filters and a bunch of what appears to be adapter rings. Purchase processing continental us AK, hi and pr shipping cost would need to be determined.

Everything is untested and being sold in as condition with no return.

part #: 9524a price

  • $77.62

specifications raditeselec:

  • model: 9524a
  • country/region of manufacture: United Kingdom
  • type: Photomultiplier Tubes

Ratings:

  1. Great buyer, quick payment 07-30-17
  2. Highly recommended. 07-23-17
  3. COOL 07-22-17
  4. Thank you for the deal!!! Very helpful seller!!! 08-01-17
  5. Hope to deal with you again. Thank you. 07-19-17

Shipping raditeselec:

  • cost: $12.0
  • type: Flat
  • handling: 1 days

General raditeselec:

  • condition: Used
  • in stock: Yes
  • businessindustrial > electricaltest equipment > test equipment business industrial > radiation testers test equipment

Seller raditeselec:

  • city: Winston-Salem, North Carolina
  • zipcode: 27106

Offer raditeselec:

  • bids: 0
  • Sold: 0
  • best offer: true
  • quantity: 1
  • Started: August 4, 2017, 8:32 am

Returns raditeselec:

  • policy: no returns

Payments raditeselec:

  • PayPal
country/region of manufacture: united kingdom, type: photomultiplier tubes, category: business & industrial > electrical test equipment > test equipment business industrial > radiation testers test equipment, sku: 796652294895282,
Review#1 Great buyer, quick payment ()
Review#2 Highly recommended A . ()
Review#3 COOL ()
Review#4 Thank you for the deal!!! Very helpful seller!!! ()
Review#5 Hope to deal with you again. Thank you. ()
raditeselec logo
1 offer $77.62 USD
  • New. Offer #1 priced at $77.62 + $13.05 shipping estimate = $90.67* total. NOS USGI surplus.+$13.05 shipping

Copyright © raditeselec.com